TM 5-3805-261-23-1
ELECTRICAL SYSTEM TROUBLESHOOTING PROCEDURES - CONTINUED
0008 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5.
Check wiring harness.
Repair horn wiring harness if cracked,
22. Backup Alarm Fails to
Operate with Transmission in
Replace wiring harness as necessary (WP
Reverse - Continued.
0285 00). If the problem still exists, go to
Test 6.
6.
Check backup alarm.
Replace backup alarm if damaged or
1.
Check console lamp bulb.
Replace console lamp bulb if burned out
23. Console Light Does Not
Operate.
go to Test 2.
2.
Check main circuit breaker (60A).
Reset circuit breaker. If the problem still
exists, go to Test 3.
3.
Test continuity of console light
switch. Connect one multimeter lead
does not have continuity. Replace light
to back of switch and one to ground.
1.
Test continuity of floodlight switch.
24. Floodlight Switch Does Not
Connect one multimeter lead to
Operate.
does not have continuity. Replace
switch and one to ground.
problem still exists, go to Test 2.
2.
Test continuity of wire assemblies.
Connect multimeter to each end of
does not have continuity. Replace wire
wire leads.
1.
Test continuity of ether control
25. Ether Control Switch Does
switch. Connect one lead of
Not Operate.
does not have continuity. Replace ether
ground.
problem still exists, go to Test 2.
2.
Test continuity of wire assemblies.
Connect multimeter to each end of
does not have continuity. Repair or
wire assembly.
1.
Test continuity of disconnect switch.
26. Battery Disconnect Switch
Connect one lead of multimeter to
Does Not Operate.
switch and one lead to ground.
problem still exists, go to Test 2.
2.
Test continuity of wire assemblies.
Connect multimeter to each end of
does not have continuity. Repair or
wire assembly.
1.
Test continuity of start switch.
27. Start Switch Does Not
Connect one lead of multimeter to
Operate.
does not have continuity, replace start
switch and one lead to ground.
exists, go to Test 2.
2.
Test continuity of wire assemblies.
Connect multimeter to each end of
wire assembly.