TM 5-3805-261-23-1
ELECTRICAL SYSTEM TROUBLESHOOTING PROCEDURES - CONTINUED
0008 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
d. Inspect and clean ground
If starter is still inoperative, go to Test 4.
5.
Starting Motor Is Inoperative
connections on back of starter and
- Continued.
tighten nut.
3.
Test starter circuit source voltage.
a. Place battery disconnect switch in
OFF position.
negative lead to chassis ground.
d. Place battery disconnect switch in
If battery voltage is indicated, go to Test 5.
ON position.
G
MTR
S
CONNECTOR
(+)
(-)
BAT
397-2422
e. Check battery connections.
Repair or replace broken wire(s) between
f. If battery disconnect switch and
If the problem still exists, go to Test 4.
connections are OK, check wiring
4.
Check starting motor voltage.
a. Connect meter positive lead to
negative lead to chassis ground.
b. Place battery disconnect switch to
ON position.