TM 5-3805-261-20
STARTING MOTOR MAINTENANCE.
7-13.
Solenoid (Prestolite). (Sheet 4 of 4)
2.
Push
pinion
back
to
eliminate
slack.
Clearance must be 0.020 to 0.50 inch
(Figure 7-25).
3.
Adjust pinion clearance. Turn lock nut (9)
with fabricated adapter tool until specified
tolerance is made.
TESTING
NOTE
An
interference
block
must
be
fabricated to test the solenoid. Refer
to Appendix D.
1.
Connect solenoid (13, Figure 7-26).
2.
Install interference block (Figure 7-27).
3.
Close switch. Replace solenoid (13, Figure
7-26) if test lamp lights.
4.
Install new preformed packing (8) and plug
(7, Figure 7-28).
NOTE
Return
130G
Grader
to
original
equipment condition.
Figure 7-25.
Figure 7-27.
Figure 7-28.
End of Task
7-47
Figure 7-26.