TM 5-3805-261-20STARTING MOTOR MAINTENANCE.7-12.Solenoid (Delco-Remy).(Sheet 3 of 3)INSTALLATION1.Position solenoid (8). Slide plunger intosolenoid (8) and aline mounting holes onstarting motor (9, Figure 7-21).2.Install four screws (7).3.Install connector (6), two lockwashers (5)and nuts (4) Tighten two nuts (4) to 22 ft-lbtorque.4.Position wire assembly (3) on G terminalstud of solenoid (8).5.Install lockwasher (2) and nut (1).NOTEReturn 130G Grader to originalequipment condition.End of Task7-43