TM 5-3805-261-20
STARTING MOTOR MAINTENANCE. (cont)
7-12.
Soleniod (Delco-Remy). (Sheet 2 of 3)
REMOVAL
1.
Remove nut (1) add lockwasher (2) from
solenoid (8, Figure 7-21).
NOTE
All
wire,
cable
and
harness
assemblies must be tagged before
disconnecting to aid in installation.
2.
Disconnect wire assembly (3) at terminal.
3.
Remove two nuts (4), lockwashers (5) and
connector (6).
4.
Remove four screws (7).
5.
Remove
solenoid
(8).
Carefully
pull
solenoid (8) off
plunger
mounted
in
starting motor (9) housing.
CLEANING
Clean all parts. Refer to Chapter 2.
INSPECTION
Inspect all parts. Refer to Chapter 2.
Figure 7-21.
Go to Sheet 3
7-42