TM 5-3805-293-23-5
0304
CLEANING AND INSPECTION
000304
N OT E
Remove and inspect each circle guide shoe wearstrip one at a time.
Replace circle guide shoe wearstrips if there is uneven wear.
The circle guide shoe wearstrips should be in complete contact with the blade circle at all
points.
If any wearstrip is not in complete contact with the blade circle, replace the wearstrip.
1. Clean and inspect all parts IAW Mechanical General Maintenance Instructions (WP 0346).
2. Measure thickness of circle guide shoe wearstrips on both contact sides, and replace if the difference between
ends exceeds 0.2 in. (3 mm).
END OF TASK
INSTALLATION
000304
1. Install wearstrip (Figure 1, Item 3) on circle guide shoe (Figure 1, Item 2).
2. With assistance, install circle shoe (Figure 1, Item 2), three washers (Figure 1, Item 5), and bolts (Figure 1,
Item 4) on drawbar (Figure 1, Item 1).
3. Repeat steps for remaining circle guide shoes.
END OF TASK
0304-3