TM 5-3805-293-23-2
0031
Table 1. Implement Code (2200-00 TO 2954-14) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2252-13 Machine Articula-
Test Step 2. Inspect Sensor and
tion Angle Sensor #2 Out of
Linkage.
1. Inspect articulation angle position
sensor 2 (right) (WP 0009, Figure
123) and linkage for the following:
Linkage Loose or Sensor Not
a. Linkage securely connected
to machine and to sensor.
Secure - Tighten articulation angle
position sensor 2 (right) and install
linkage (WP 0257).
Proceed to step 2.
b. Linkage bent or damaged.
Linkage Bent or Damaged - Replace
articulation angle position sensor 2
(right) linkage (WP 0257).
Proceed to step 2.
Sensor and Linkage OK - Proceed to
Test Step 3.
2. Using MSD (WP 0006), select
2252-13 Code Active - Repeat
Implement 120M and verify 2252- troubleshooting from the beginning of
13 is active.
this diagnostic code.
2252-13 Code Not Active -
Troubleshooting complete.
Test Step 3. Check Sensor.
1. Verify articulation angle position
Articulation Angle Position Sensor
sensor is within specifications
OK - Proceed to Test Step 3.
refer to Adjustment in WP 0257.
Articulation Angle Position Sensor
Needs Adjustment - Adjust sensor
as directed (WP 0257).
Proceed to step 2.
2. Using MSD (WP 0006), select
2252-13 Code Active - Repeat
Implement 120M and verify 2252- troubleshooting from the beginning of
13 is active.
this diagnostic code.
2252-13 Code Not Active -
Troubleshooting complete.
0031-151