Table 1. Implement Code (0041-03 to 0600-04) Troubleshooting Procedures - Continued.
Table 1. Implement Code (0041-03 to 0600-04) Troubleshooting Procedures - Continued.

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  518    519    520    521    522  523  524    525    526    527    528  
img
TM 5-3805-293-23-2
0026
Table 1. Implement Code (0041-03 to 0600-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0490-04 Implement Lock Out
8. Using the MSD (WP 0006), select  0490-04 Code Active - Repeat
Switch Voltage Below
Implement 120M and verify 0490- troubleshooting code from the
Normal - Continued
04 is not active.
beginning.
0490-04 Code Not Active -
Troubleshooting complete.
System Response:
0588-09 Monitoring System
Display Abnormal Update
ECM will log a diagnostic code.
Rate
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is Active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Verify if Code 0588-09
is Active.
1. Connect MSD (WP 0006). Select  0588-09 Code Active - Proceed to
Implement 120M and verify 0588- Test Step 2.
09 is active.
0588-09 Code Not Active -
Troubleshooting complete.
Test Step 2. Test Voltage Supply
and Ground Circuits.
1. Turn ignition switch and battery
disconnect switch to the OFF
position (TM 5-3805-293-10).
2. Disconnect cab lower wiring har-
ness connector P-C93 (WP 0009,
Figure 163) from messenger (WP
0009, Figure 164) (WP 0272).
3. Turn battery disconnect switch
and ignition switch to the ON posi-
tion (TM 5-3805-293-10).
4. Using digital multimeter, test for
Voltage OK - Proceed to step 5.
voltage between harness connec-
Voltage Less Than 18 Volts -
tor P-C93 (WP 0009, Figure 163)
Replace cab lower wiring harness
terminal 1 and machine ground.
(WP 0266).
Voltage should be 18-26 volts.
Proceed to step 8.
0026-62