Table 1. Implement Code (0041-03 to 0600-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0588-09 Monitoring System
Voltage OK - Proceed to step 6.
Display Abnormal Update
voltage between harness connec-
Voltage Less Than 18 Volts -
Rate - Continued
tor P-C93 (WP 0009, Figure 163)
Replace cab lower wiring harness
terminal 3 and machine ground.
(WP 0266).
Voltage should be 18-26 volts.
Proceed to step 8.
6. Turn ignition switch and battery
disconnect switch to the OFF
position (TM 5-3805-293-10).
continuity between harness con-
nector P-C93 (WP 0009, Figure
wiring harness (WP 0266).
163) terminal 2 and machine
Proceed to step 8.
ground.
5.0 ohms.
8. Using MSD (WP 0006), select
0588-09 Code Remains Active -
Implement 120M and verify 0588- Repeat troubleshooting from the
09 is not active.
beginning of this diagnostic code.
0588-09 Code Not Active -
Troubleshooting complete.
Test Step 3. Test Data Link Circuit.
1. Disconnect harness connector P-
C41 (WP 0009, Figure 68) from
implement ECM J1 (WP 0006,
Figure 69).
2. Install a jumper wire between har-
ness connector P-C93 (WP 0009,
Figure 163) terminals 5 and termi-
nal 6.
continuity between harness con-
Replace messenger (WP 0272) and
nector P-C41 (WP 0009, Figure
implement 1 ECM (WP 0268).
68) terminal 10 and terminal 20.
Proceed to step 4.
5.0 ohms.
Replace cab lower wiring harness
(WP 0266).
Proceed to step 4.
4. Using MSD (WP 0006), select
0588-09 Code Remains Active -
Implement 120M and verify 0588- Repeat troubleshooting from the
beginning of this diagnostic code.
09 is not active.
0588-09 Code Not Active -
Troubleshooting complete.