TM 5-3805-293-23-2
0026
Table 1. Implement Code (0041-03 to 0600-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0588-14 Monitoring System
System Response:
Display Special Instruction
ECM will log a diagnostic code.
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is Active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Verify if Code 0588-14
is Active.
1. Connect MSD (WP 0006). Select 0588-14 Code Active - Proceed to
Implement 120M and verify 0588- step 2.
14 is active.
0588-14 Code Not Active -
Troubleshooting complete.
2. Program the implement ECM and
the messenger (WP 0008).
3. Using MSD (WP 0006), select
0588-14 Code Active - Replace the
Implement 120M and verify 0588- implement 1 ECM (WP 0268) and the
14 is not active.
messenger (WP 0272).
0588-14 Code Not Active -
Troubleshooting complete.
0026-64