TM 5-3805-293-23-2
0026
Table 1. Implement Code (0041-03 to 0600-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0248-14 SAE J1939 Data
2. Using MSD (WP 0006), select
0296-14 Code Active - Perform
Link Special Instruction
Implement Control #2 120M and
troubleshooting procedure for 0296-
(Implement 2) - Continued
verify 0296-14, 0588-14, or 0590-
14 in this work package.
14 are active.
0588-14 Code Active - Perform
troubleshooting procedure for 0588-
14 in this work package.
0590-14 Code Active - Perform
troubleshooting procedure for 0590-
14 in this work package.
0262-03 5 Volt DC Power
System Response:
Supply Voltage Above Nor-
ECM will log diagnostic code.
mal
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Test 5-Volt Supply Cir-
cuit.
1. Connect MSD (WP 0006). Select
Implement 120M ECM and verify
0262-03 is active.
2. Turn ignition switch and battery
disconnect switch to the OFF
position (TM 5-3805-293-10).
3. Disconnect accumulator sensor
harness connector FG-C2 (WP
0009, Figure 137) from accumula-
tor pressure sensor (WP 0009,
Figure 138) (WP 0233).
4. Disconnect harness connector
FA-C20 (WP 0009, Figure 113)
from transmission ECM J1 (WP
0009, Figure 112) (WP 0137).
0026-32