TM 5-3805-293-23-2
0026
Table 1. Implement Code (0041-03 to 0600-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0248-09 Data Link Abnormal
Test Step 1. Verify if Code 0248-09
Update Rate (Implement 2) -
is Active.
Continued
1. Connect MSD (WP 0006). Select
0248-09 Code Active - Proceed to
Implement Control #2 120M and
step 2.
verify 0248-09 is active.
0248-09 Code Not Active -
Troubleshooting complete.
2. Using MSD (WP 0006), select
0296-09 Code Active - Perform
Implement Control #2 120M and
troubleshooting procedure for 0296-
verify 0296-09, 0588-09, 0590-09
09 in this work package.
or 1558-09 are active.
0588-09 Code Active - Perform
troubleshooting procedure for 0588-
09 in this work package.
0590-09 Code Active - Perform
troubleshooting procedure for 0590-
09 in this work package.
1558-09 Code Active - Perform
troubleshooting procedure for 1558-
0248-14 SAE J1939 Data
System Response:
Link Special Instruction
ECM will log a diagnostic code.
(Implement 2)
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is Active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Verify if Code 0248-14
is Active.
1. Connect MSD (WP 0006). Select
0248-14 Code Active - Proceed to
Implement Control #2 120M and
Step 2.
verify 0248-14 is active.
0248-14 Code Not Active -
Troubleshooting complete.
0026-31