Table 1. Implement Code (0041-03 to 0600-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0247-09 SAE J1939 Data
System Response:
Link Abnormal Update Rate
ECM will log a diagnostic code and a
warning will appear on the instrument
panel.
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is Active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Verify if Code 0247-09
is Active.
1. Connect MSD (WP 0006). Select  0247-09 Code Active - Proceed to
Implement 120M and verify 0247- Step 2.
09 is active.
0247-09 Code Not Active -
Troubleshooting complete.
0296-09 Code Active - Perform
2. Using MSD (WP 0006), select
troubleshooting procedure for 0296-
Implement 120M and verify 0296-
09 in this work package.
09 or 590-09 or 1558-09 are
active.
0590-09 Code Active - Perform
troubleshooting procedure for 0590-
09 in this work package.
1558-09 Code Active - Perform
troubleshooting procedure for 1558-
09 in WP 0027.