TM 5-3805-293-23-1
0017
Table 1. Transmission Code (0573-03 to 0967-09) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0615-02 Machine Articula-
System Response:
tion Angle Sensor Data
ECM will log a diagnostic code.
Erratic, Intermittent or Incor-
N OT E
rect
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is Active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Verify if Code 0615-02
is Active.
0041-03 or 0041-04 Code Active -
Diagnose 0041-03 or 0041-04 (WP
Implement 120M and verify 0041-
0025 01) for the Implement ECM first.
03 or 0041-04 are active in the
Implement 120M ECM.
0041-03 or 0041-04 Code Not Active
- Proceed to step 2.
0615-02 Code Active - Proceed to
Test Step 2.
0615-02 is active for the transmis-
sion ECM or the Implement 1
0615-02 Code Not Active - Trouble-
ECM.
shooting complete.
Test Step 2. Inspect Sensor and
Linkage.
1. Inspect articulation angle position
145) and linkage for the following:
a. Linkage securely connected
Linkage Loose or Sensor Not
to machine and to sensor.
Secure - Perform installation and
adjustment procedures for articula-
tion angle position sensor 1 (left) (WP
0257).
Proceed to step 2.
b. Remove articulation angle
Sensor Damaged - Replace articula-
position sensor 1 (left) and
tion angle position sensor 1 (left) (WP
visually inspect sensor hous-
0257).
ing, and harness connector
Proceed to step 2.
for damage (WP 0257).