• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. Transmission Code (0041-03 to 0444-06) Troubleshooting Procedures - Continued.
Table 1. Transmission Code (0041-03 to 0444-06) Troubleshooting Procedures - Continued.

Maintenance Manual For Motorized Road Grader Model 120M - 1
Page Navigation
  895    896    897    898    899  900  901    902    903    904    905  
img
. . . . . . . . . .
TM 5-3805-293-23-1
0016
Table 1. Transmission Code (0041-03 to 0444-06) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0444-06 Starter Motor Relay
System Response:
Current Above Normal
ECM will log diagnostic code.
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a
connection is found, correct the problem and verify that this diagnostic
code is active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Test Relay Control.
1. Connect MSD (WP 0006). Select
Trans/Chassis 120M ECM and
verify 0444-06 is active.
2. Turn ignition switch to the OFF
position.
3. Disconnect harness connector
FA-C41 (WP 0009, Figure 21)
from circuit breaker box harness
connector R-C5 (WP 0009, Figure
22) (WP 0234).
4. Disconnect harness connector
FA-C21 (WP 0009, Figure 124)
from transmission ECM J2 (WP
0009, Figure 112) (WP 0137).
5. Using digital multimeter, test for
Continuity - Replace rear chassis
continuity between harness con-
wiring harness (WP 0188).
nector FA-C21 (WP 0009, Figure
Proceed to step 7.
124) terminal 5 and all other ter-
No Continuity - Replace transmis-
minals on harness connector FA-
sion ECM (WP 0137).
C21, and to machine ground.
Connect harness connector FA-C41
There should be no continuity.
(WP 0009, Figure 21) to circuit
breaker box harness connector R-C5
(WP 0009, Figure 22) (WP 0234).
Proceed to step 6.
0016-56


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.