Table 1. Transmission Code (0041-03 to 0444-06) Troubleshooting Procedures - Continued.
TRANSMISSION CODE (0573-03 TO 0967-09) TROUBLESHOOTING PROCEDURES

Maintenance Manual For Motorized Road Grader Model 120M - 1
Page Navigation
  896    897    898    899    900  901  902    903    904    905    906  
img
. . . . . . .
TM 5-3805-293-23-1
0016
Table 1. Transmission Code (0041-03 to 0444-06) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0444-06 Starter Motor Relay
6. Using digital multimeter, test for
Continuity - Replace circuit breaker
Current Above Normal -
continuity between circuit breaker
box wiring harness (WP 0239).
Continued
box harness connector R-C5 (WP
Connect harness connector FA-C21
0009, Figure 22) and machine
(WP 0009, Figure 124) to transmis-
ground.
sion ECM J2 (WP 0009, Figure 112)
There should be no continuity.
(WP 0137).
Proceed to step 7.
No Continuity - Replace transmis-
sion ECM (WP 0137).
Connect harness connector FA-C41
(WP 0009, Figure 21) to circuit
breaker box harness connector R-C5
(WP 0009, Figure 22) (WP 0234).
Proceed to step 7.
7. Using MSD (WP 0006), select
0444-06 Code Active - Repeat trou-
Trans/Chassis 120M ECM and
bleshooting code from the beginning.
verify 0444-06 is active.
0444-06 Code Not Active - Trouble-
shooting complete.