TM 5-3805-26314&LP-3
OPERATOR'S STATION
GAUGE GROUP
REMOVE GAUGE GROUP
Make sure the air pressure in the system is zero
before any lines are disconnected.
1.
Disconnect hoses (2) and (3) from the air pressure
gauges.
2.
Disconnect wiring harness (1) from the gauge
group.
3.
Remove four bolts (4) and gauge panel (5) from
plate assembly.
4.
Remove the air pressure gauges (7), service meter
(6), and coolant temperature gauge (8) by removing
nuts and brackets from gauge panel. Remove
gauges.
INSTALL GAUGE GROUP
1. Put air pressure gauges (2), service meter (1) and
coolant temperature gauge (3) in position in panel
and install brackets and nuts to hold them in
position.
2.
Put gauge panel (4) in position in plate assembly
and install bolts.
3.
Connect wiring harness (5) to the gauge panel.
4.
Install hoses (6) and (7) to the air pressure gauges.
4-89