HYDRAULIC SYSTEM MAINTENANCE. (cont)
10-10.
Hydraulic Control Valves. (Sheet 6 of 11)
DISASSEMBLY (cont)
26.
Remove plug (45) and preformed
packing (46, Figure 10-87).
Discard preformed packing (46).
27.
Remove four bolts (47 and 48) and
cover (49).
28.
Remove and discard two preformed
packings (50) and preformed
packing (51).
29.
Remove spool (52).
30.
Using 8/32 2B THD screw and
puller, remove items 53 and 54 as
an assembly.
31.
Remove and discard two preformed
packings (53) from valve assembly
(54, Figure 10-88).
CLEANING
Clean all parts. Refer to Chapter 2.
INSPECTION
Inspect all parts. Refer to Chapter
2.
ASSEMBLY
1.
Install two new preformed
packings (53) on valve assembly
(54, Figure 10-88).
2.
Using clean oil, lubricate outer
diameters of two new preformed
packings (53).
Go to Sheet 7
Figure 10-87.
Figure 10-88.
10-62