TM 5-3805-261-34STARTING SYSTEM MAINTENANCE.4-9.StartingMotor(Delco-Remy). (Sheet 15 of 15)ADJUSTMENT1.Disconnect wire assembly (11,Figure 4-53) from solenoid.2.Connect solenoid to 24 voltbattery, as shown, using threejumper wires. Do not connectground to MTR terminal at thistime.Check pinion clearance quicklyto avoid damage to solenoidwindings.3.Momentarily flash jumper wire "A"from ground to MTR terminal.Drive (48, Figure 4-54) willshift into cranking position.4.Press drive (48) in direction ofarrow to take up slack.5.Using thickness gage, measurepinion clearance.6.Adjust lock nut (3) until correctclearance.7.Remove three jumper wires (Figure4-53).8.Install new preformed packing (2)and plug (1) in housing (58,Figure 4-55).9.Connect wire assembly (11, Figure4-56) to solenoid ground.NOTEReturn 130G Grader tooriginal equipment condition.End of Task4-51CAUTIONFigure 4-53.Figure 4-54.Figure 4-55.Figure 4-56.