TM 5-3805-261-34
STARTING SYSTEM MAINTENANCE.
4-9.
Starting Motor (Delco-Remy). (Sheet 15 of 15)
ADJUSTMENT
1.
Disconnect wire assembly (11,
Figure 4-53) from solenoid.
2.
Connect solenoid to 24 volt
battery, as shown, using three
jumper wires. Do not connect
ground to MTR terminal at this
time.
Check pinion clearance quickly
to avoid damage to solenoid
windings.
3.
Momentarily flash jumper wire "A"
from ground to MTR terminal.
Drive (48, Figure 4-54) will
shift into cranking position.
4.
Press drive (48) in direction of
arrow to take up slack.
5.
Using thickness gage, measure
pinion clearance.
6.
Adjust lock nut (3) until correct
clearance.
7.
Remove three jumper wires (Figure
4-53).
8.
Install new preformed packing (2)
and plug (1) in housing (58,
Figure 4-55).
9.
Connect wire assembly (11, Figure
4-56) to solenoid ground.
NOTE
Return 130G Grader to
original equipment condition.
End of Task
4-51
CAUTION
Figure 4-53.
Figure 4-54.
Figure 4-55.
Figure 4-56.