TM 5-3805-261-34FUEL SYSTEM MAINTENANCE.3-27.GovernorandFuelInjectionPump. (Sheet 3 of 9)STATIC FUEL ADJUSTMENT6.Install dial indicator in collet(Figure 3-103). Tighten colletjust enough to hold dialindicator.7.Move governor control lever (5,Figure 3-104) to shut-off posi-tion.8.Install timing pin (Figure3-105). Position throughindicator bracket hole into zerorack pin hole in injection pump(Figure 3-101). Push timing pinin until contact with fuel rackis made.9.Move governor control lever (5,Figure 3-104) to high idle. Fuelrack (Figure 3-101) will moveagainst timing pin and stop.10. Position and hold. Fuel rack isnow in zero position.Go to Sheet 43-137Figure 3-103.Figure 3-104.Figure 3-105.