TM 5-3805-261-34FUEL SYSTEM MAINTENANCE. (cont)3-27. GovernorandFuelInjectionPump. (Sheet 2 of 9)TEST/ADJUSTCheck fuel injection pump timing.Refer to paragraph 3-7.NOTEPerform static fuel adjust-ment if governor or fuelinjection pump have beenrepaired.STATIC FUEL ADJUSTMENT1.Remove secondary fuel filter (1,Figure 3-99) from fuel injectionpump.2.Remove four bolts (2), cover (3)and gasket (4). Discard gasket(4). Remove all gasket materialfrom mounting surfaces.3.Install collett on indicatorbracket (Figure 3-100).4.Install indicator bracket.Engage bracket lever in fuel rackslot (Figure 3-101). Tightenbracket to pump housing. Thelever on indicator bracket(Figure 3-100) must move smoothlywhen governor control is movedfrom high to low idle.5.Install contact point on dialindicator (Figure 3-102).Go to Sheet 3 Figure 3-102.3-136Figure 3-99.Figure 3-100.Figure 3-101.