TM 5-3805-261-34ENGINE MAINTENANCE.3-13.Valves. (Sheet 8 of 8)TESTINGMark rotocoil assembly (2) with chalk. Tap lightlywith soft-tip plastic hammer six to eight times.NOTERotocoil assembly must turnwhen tapped with hammerseveral times. Replace rotocoilassembly if it does not turn.Return 130G Grader to originalequipment condition.End of Task3-85