TURBOCHARGER REPLACEMENT - CONTINUED
ELECTRONIC MONITORING SYSTEM (EMS) PANEL REPAIR - CONTINUED

Maintenance Manual For Grader, Road, Motorized, Diesel Engine Driven, Heavy, Commercial Construction Equipment
Page Navigation
  105    106    107    108    109  110  111    112    113    114    115  
img
. . . . . . . . . .
TM 5-3805-261-23-2
ELECTRONIC MONITORING SYSTEM (EMS) PANEL REPAIR
0284 00
THIS WORK PACKAGE COVERS
Disassembly, Cleaning and Inspection, Assembly
INITIAL SETUP
References
Maintenance Level
Direct Support
WP 0021 00
Tools and Special Tools
Equipment Conditions
Tool kit, general mechanic's (Item 89, WP 0348 00)
Machine parked on level ground (TM 5-3805-261-
Shop equipment, field maintenance (Item 75, WP
10)
0348 00)
Parking/emergency brake applied (TM 5-3805-261-
Wrench, torque (Item 98, WP 0348 00)
10)
Materials/Parts
Implements lowered to ground (TM 5-3805-261-
Silicone compound (Item 41, WP 0349 00)
10)
Rag, wiping (Item 35, WP 0349 00)
Engine off (TM 5-3805-261-10)
Sealing compound (Item 39, WP 0349 00)
Battery cables disconnected (WP 0125 00)
Packing, preformed (2)
Washer, key (9)
Electronic monitoring system panel removed (WP
Washer, seal
0069 00)
DISASSEMBLY
1.
Remove plug (5) and preformed packing (6) from
cover (3). Discard preformed packing.
2.
Remove four stud bolts (4), cover (3), and preformed
1
packing (7). Discard preformed packing.
2
3.
Remove and discard seal washer (2) from connector
(1).
7
3
4
6
5
397-4083
0284 00-1