TM 5-3805-261-23-2
ELECTRONIC MONITORING SYSTEM (EMS) PANEL REPAIR - CONTINUED
0284 00
DISASSEMBLY - CONTINUED
4.
Remove nine screws (9), key washers (10), magnet
8
(11), and housing (8). Discard key washers.
11
1
10
9
397-4084
CLEANING AND INSPECTION
Clean and inspect all parts in accordance with WP 0021 00.
ASSEMBLY
1.
Apply silicone (heat transfer) compound to corner of magnet (11) where transistor and heat sink are located. Apply
thread sealant to nine screws (9). Install housing (8), magnet, nine new key washers (10), and screws.
2.
Install new seal washer (2) on connector (1). Tighten
to 72 lb-in. (8 Nm).
3.
Install new preformed packing (7), cover (3), and four
1
stud bolts (4). Tighten stud bolts to 48 lb-in. (5 Nm).
2
4.
Install new preformed packing (6) and plug (5).
7
3
4
6
5
397-4083
5.
Install EMS panel (WP 0069 00).
6.
Connect battery cables (WP 0125 00).
END OF WORK PACKAGE
0284 00-2