GOVERNOR CONTROLS MAINTENANCE - CONTINUED
0282 00
ADJUSTMENT
1.
Disconnect rod assembly (4) from governor lever (8).
2.
Position governor lever (8) in low idle position.
3.
Start engine and ensure low idle RPMs are within specifications.
4.
Shut off engine.
5.
Disconnect cable end (53) from housing (55).
4
HIGH IDLE
5
55
15.25 IN.
(38.7 CM)
SHUTOFF
0.75 IN.
8
(19.0 MM)
7
LOW IDLE
53
397-2280
6.
Adjust rod assembly (4) to 15.25 in. (38.7 cm).
7.
Connect rod assembly (4) to governor lever (8).
8.
Install pin (5) and new cotter pin (7).