TM 5-3805-261-23-1
PRIMARY FUEL FILTER/PRIMING PUMP AND MOUNTING MAINTENANCE
(MODELS 130GS AND 130GNS)
THIS WORK PACKAGE COVERS
Removal, Disassembly, Cleaning and Inspection, Assembly, Installation
INITIAL SETUP
Maintenance Level
References
Unit
Tools and Special Tools
Equipment Conditions
Machine parked on level ground (TM 5-3805-261-
10)
Materials/Parts
Parking/emergency brake applied (TM 5-3805-261-
10)
Implements lowered to ground (TM 5-3805-261-
10)
Filter element
Engine off (TM 5-3805-261-10)
Battery disconnect switch in OFF position (TM 5-
Gasket
3805-261-10)
Packing, preformed (3)
Right side engine doors opened (TM 5-3805-261-
10)
WARNING
DO NOT smoke or permit any open flame in area of machine while you are servicing fuel system. Be
sure hose nozzle is grounded against filler tube during refueling to prevent static electricity. Failure to
follow this warning may result in injury or death to personnel or damage to equipment.
DO NOT perform fuel system checks, inspections, or maintenance while smoking or near fire, flames,
or sparks. Fuel may ignite, causing injury or death to personnel or damage to equipment.
Operating personnel must wear fuel-resistant gloves when handling fuel. If exposed to fuel, promptly
wash exposed skin and change fuel-soaked clothing.