TM 5-3805-261-20WIRING HARNESS MAINTENANCE. (cont)7-117.GeneralRepair. (Sheet 3 of 15)(2)Connectors with ring-type terminals.DISASSEMBLYRemove and discard defective terminal (Figure7-192). Cut wire close to terminal.ASSEMBLYNOTENew terminal must be selected tomatch the ring size of the terminalwith the mounting screw at theterminal connection. New terminalmust also match the crimp tabs withthe thickness of the wire.1.Strip wire, refer to chart (Figure 7-191). Donot cut or nick wire strands.2.Tin bare wires. Use resin-core solder tocoat bare wires. If using solid core solder,clean wires with flux before tinning.3.Insert in new terminal.4.Crimp securely to fasten wire to new crimp-type insulated terminal.5.Solder to new solder type terminal. Securewire and terminal to prevent movement.Use solder sparingly.Figure 7-192Figure 7-191Go to Sheet 47-294