TM 5-3805-261-20
WIRING HARNESS MAINTENANCE. (cont)
7-117.
General Repair. (Sheet 3 of 15)
(2)
Connectors with ring-type terminals.
DISASSEMBLY
Remove and discard defective terminal (Figure
7-192). Cut wire close to terminal.
ASSEMBLY
NOTE
New terminal must be selected to
match the ring size of the terminal
with the mounting screw at the
terminal connection. New terminal
must also match the crimp tabs with
the thickness of the wire.
1.
Strip wire, refer to chart (Figure 7-191). Do
not cut or nick wire strands.
2.
Tin bare wires. Use resin-core solder to
coat bare wires. If using solid core solder,
clean wires with flux before tinning.
3.
Insert in new terminal.
4.
Crimp securely to fasten wire to new crimp-
type insulated terminal.
5.
Solder to new solder type terminal. Secure
wire and terminal to prevent movement.
Use solder sparingly.
Figure 7-192
Figure 7-191
Go to Sheet 4
7-294