TM 5-3805-293-23-5
0294
INSTALLATION CONTINUED
23. Install blower motor resistor (Figure 33, Item 2) and tighten locknut (Figure 33, Item 3) on blower motor plate
(Figure 33, Item 4).
24. Connect four blower motor resistor wires (Figure 33, Item 1) to blower motor resistor (Figure 33, Item 2).
25. Install two new tiedown straps (Figure 33, Item 5) on blower motor plate (Figure 33, Item 4).
26. Install new rubber strip (Figure 33, Item 6) on heater and evaporator cores (Figure 33, Item 7).
Figure 33. Blower Motor Resistor.
0294