TM 5-3805-293-23-4
0239
REMOVAL CONTINUED
2. Remove two bolts (Figure 2, Item 3) and washers (Figure 2, Item 4) from circuit breaker box (Figure 2,
Item 1).
3. Remove four bolts (Figure 2, Item 5) and washers (Figure 2, Item 6) from circuit breaker box (Figure 2,
Item 1) and open upper cover (Figure 2, Item 2).
Figure 2. Upper Circuit Breaker Box Cover.
0239
4. Remove four nuts (Figure 3, Item 1), washers (Figure 3, Item 4), wiring eyelets (Figure 3, Item 2) and
Figure 3. Upper Circuit Breaker Wiring Connections.
0239