TM 5-3805-293-23-4
0239
REMOVAL CONTINUED
10. Remove tiedown strap (Figure 6, Item 15) from wiring harness (Figure 6, Item 14).
11. Remove nut (Figure 6, Item 19) and cable (Figure 6, Item 1) from magnetic switch (Figure 6, Item 18).
12. Remove nut (Figure 6, Item 17) and cable (Figure 6, Item 16) from magnetic switch (Figure 6, Item 18).
13. Remove bolt (Figure 6, Item 20), washer (Figure 6, Item 21) and two harness clips (Figure 6, Item 2) from
circuit breaker box (Figure 6, Item 22).
14. Disconnect two harness connectors (Figure 6, Item 3) from pigtails (Figure 6, Item 4).
15. Remove two connectors (Figure 6, Item 3) from harness clips (Figure 6, Item 2).
16. Remove nut (Figure 6, Item 7), wiring eyelet (Figure 6, Item 5) and lockwasher (Figure 6, Item 6) from start
relay (Figure 6, Item 13). Discard lockwasher.
17. Remove nut (Figure 6, Item 8), wiring eyelet (Figure 6, Item 10) and lockwasher (Figure 6, Item 9) from start
relay (Figure 6, Item 13). Discard lockwasher.
18. Disconnect transmission harness connector (Figure 6, Item 11) from bulkhead connector (Figure 6, Item 12).
Figure 6. Circuit Breaker Box Wiring Connections.
0239