TM 5-3805-293-23-3
0159
INSTALLATION
000159
WARN I N G
Use extreme caution when handling heavy parts. Provide adequate support and use
assistance during procedure. Failure to follow this warning may cause injury or death to
personnel.
N OT E
Charging pump weighs 75 lb (34 kg).
1. Install new O-ring (Figure 3, Item 8) on tube (Figure 3, Item 2).
2. Install new O-ring (Figure 3, Item 10) on charging pump (Figure 3, Item 9). WIth assistance, install charging
pump, three washers (Figure 3, Item 3), and bolts (Figure 3, Item 4) on transmission (Figure 3, Item 1). Torque
bolts to 41 lb-ft (55 Nm).
3. Install tube (Figure 3, Item 2), two clamps (Figure 3, Item 7), four washers (Figure 3, Item 5), and bolts
(Figure 3, Item 6) on charging pump (Figure 3, Item 9).
0159-5