Figure 2. Charging Pump Hoses.
INSTALLATION

Maintenance Manual For Motorized Road Grader Model 120M - 3
Page Navigation
  1190    1191    1192    1193    1194  1195  1196    1197    1198    1199    1200  
img
.
TM 5-3805-293-23-3
0159
REMOVAL CONTINUED
6. Remove four bolts (Figure 3, Item 5), washers (Figure 3, Item 6), two clamps (Figure 3, Item 7), and tube
(Figure 3, Item 2) from charging pump (Figure 3, Item 9).
WARN I N G
Use extreme caution when handling heavy parts. Provide adequate support and use
assistance during procedure. Failure to follow this warning may cause injury or death to
personnel.
N OT E
Charging pump weighs 75 lb (34 kg).
7. Using assistance, remove three bolts (Figure 3, Item 4), washers (Figure 3, Item 3), charging pump (Figure 3,
Item 9), and O-ring (Figure 3, Item 10) from transmission (Figure 3, Item 1). Discard O-ring.
8. Remove O-ring (Figure 3, Item 8) from tube (Figure 3, Item 2). Discard O-ring.
Figure 3. Charging Pump Tube.
0159
END OF TASK
CLEANING AND INSPECTION
000159
Clean and inspect all parts IAW Mechanical General Maintenance Instructions (WP 0346).
END OF TASK