TM 5-3805-293-23-3
0122
CLEANING AND INSPECTION
000122
Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0346).
END OF TASK
INSTALLATION
000122
1. Install ether starting valve (Figure 1, Item 3), two washers (Figure 1, Item 1), and bolts (Figure 1, Item 2) on
hydraulic service pack (Figure 1, Item 15).
2. Install clip (Figure 1, Item 12) on solenoid valve harness connector (Figure 1, Item 13) and connect to fuel
pump harness (Figure 1, Item 11).
N OT E
If equipped with arctic heater, install clamp and spacer.
3. Install clip (Figure 1, Item 12), spacer (Figure 1, Item 10), clamp (Figure 1, Item 14), washer (Figure 1, Item 6),
and bolt (Figure 1, Item 5) on hydraulic service pack (Figure 1, Item 15).
4. Install ether injection tube (Figure 1, Item 4) on ether starting valve (Figure 1, Item 3).
5. Install ether injection tube (Figure 1, Item 4), clip (Figure 1, Item 7), washer (Figure 1, Item 8) and bolt
(Figure 1, Item 9) on hydraulic service pack (Figure 1, Item 15).
N OT E
If removed, install ether cylinder (TM 5-3805-293-10).
END OF TASK
END OF WORK PACKAGE
0122-3/(4 blank)