1. Loosen two hose clamps (Figure 1, Item 4) on upper radiator hose (Figure 1, Item 2).
2. Disconnect upper radiator hose (Figure 1, Item 2) from water temperature regulator (Figure 1, Item 1).
3. Disconnect upper radiator hose (Figure 1, Item 2) from upper coolant tube (Figure 1, Item 3).
Figure 1. Upper Radiator Hose.
081
4. Remove two bolts (Figure 2, Item 4) and water temperature regulator (Figure 2, Item 3) from cylinder head
(Figure 2, Item 1).
5. Remove O-ring (Figure 2, Item 2) from water temperature regulator (Figure 2, Item 3). Discard O-ring.