TM 5-3805-293-23-3
0076
INSTALLATION
00076
WARN I N G
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may cause injury to personnel.
N OT E
If original exhaust manifold bolts are to be reused, low strength sealing compound must be
applied to bolts. Do not apply low strength sealing compound if new bolts are used.
1. Install two new gaskets (Figure 2, Item 4) and exhaust manifold (Figure 2, Item 1) on engine.
2. If reusing original bolts (Figure 2, Item 2), apply sealing compound to 12 bolts (Figure 2, Item 2).
3. Install 12 spacers (Figure 2, Item 3) and bolts (Figure 2, Item 2) on exhaust manifold (Figure 2, Item 1).
Figure 2. Exhaust Manifold and Gaskets.
0076