• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
IGNITION SYSTEM TESTS, INSPECTIONS, AND ADJUSTMENTS
ELECTRIC STARTING SYSTEM TEST CONTINUED

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  1240    1241    1242    1243    1244  1245  1246    1247    1248    1249    1250  
img
.
TM 5-3805-293-23-2
0039
ELECTRIC STARTING SYSTEM TEST
00039
General Information
00039
Power available during cranking varies according to temperature and condition of batteries
.
Table 1 shows voltages that are expected from battery at various temperature ranges.
C AU T I O N
Do not crank engine for more than 30 seconds. Allow starter to cool for 2 minutes before
cranking again. Never turn disconnect switch off while engine is running. Failure to follow
this caution may result in damage to equipment.
Test Step 1. Measure Voltage of Battery.
00039
N OT E
Do not measure voltage across cable post clamps.
1. Lift protective boots (Figure 1, Item 1) from negative battery terminal (Figure 1, Item 2) on rear battery, and
positive battery terminal (Figure 1, Item 3) on front battery.
2. Using a digital multimeter, measure voltage between the positive (Figure 1, Item 3) and negative (Figure 1,
Item 2) battery posts while cranking engine or attempting to crank engine.
a. If voltage is equal to or greater than voltage in Table 1, go to Test Step 2.
b. If battery voltage is less than voltage in Table 1, continue diagnostics.
Figure 1. Battery Test Points.
0039
0039-2


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.