Table 1. Implement Code (2200-00 TO 2954-14) Troubleshooting Procedures - Continued.
Table 1. Implement Code (2200-00 TO 2954-14) Troubleshooting Procedures - Continued.

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  985    986    987    988    989  990  991    992    993    994    995  
img
TM 5-3805-293-23-2
0031
Table 1. Implement Code (2200-00 TO 2954-14) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2202-14 Steering Valve Con-
4. Using digital multimeter, test for
Continuity - Replace front
trol Module Bad Device or
continuity between harness con-
attachment wiring harness (WP
Component - Continued
nector U-C1 (WP 0009, Figure
0183).
121) terminal 55 and all other ter-
Proceed to step 6.
minals on harness connector U-
No Continuity - Proceed to step 5.
C1 and to machine ground.
There should be no continuity.
5. Using digital multimeter, test for
Continuity - Replace front
continuity between harness con-
attachment wiring harness (WP
nector U-C1 (WP 0009, Figure
0183).
121) terminal 62 and all other ter-
Proceed to step 6.
minals on harness connector U-
No Continuity - Proceed to Test Step
C1 and to machine ground.
5.
There should be no continuity.
6. Using the MSD (WP 0006), select  2202-14 Code Active - Repeat
Implement 120M and verify 2202- troubleshooting code from the
14 is not active.
beginning.
2202-14 Code Not Active -
Troubleshooting complete.
Test Step 5. Test Steering Valve
Control Module Load Return Circuit
In Front Attachment Wiring Har-
ness.
1. Install a jumper wire between har-
ness connector U-C34 (WP 0009,
Figure 217) terminal 2, and termi-
nal 5.
2. Using digital multimeter, test for
Resistance 5.0 Ohms or Less -
continuity between harness con-
Proceed to step 3.
nector U-C1 (WP 0009, Figure
Resistance More Than 5.0 Ohms -
121) terminal 26 and terminal 62.
Replace front attachment wiring
Resistance should be less than
harness (WP 0183).
5.0 Ohms.
Proceed to step 5.
3. Remove jumper wire from har-
ness connector U-C34 (WP 0009,
Figure 217) terminal 2, and termi-
nal 5.
4. Using digital multimeter, test for
Continuity - Replace front
continuity between harness con-
attachment wiring harness (WP
nector U-C1 (WP 0009, Figure
0183).
121) terminal 26 and all other ter-
Proceed to step 5.
minals on harness connector U-
No Continuity - Proceed to Test Step
C1 and to machine ground.
6.
There should be no continuity.
0031-83