TM 5-3805-293-23-2
0030
Table 1. Implement Code (2169-03 to 2182-13) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2172-06 Articulate Right
Test Step 4. Test for Shorted Front
Attachment Wiring Harness.
Normal - Continued
1. Disconnect front attachment wir-
ing harness connector U-C1 (WP
0009, Figure 121) from cab lower
wiring harness connector P-C50
(WP 0009, Figure 120) (WP
0180).
sure for continuity between front
attachment wiring harness (WP
attachment wiring harness con-
0180).
nector U-C1 (WP 0009, Figure
Connect cab lower wiring harness
121) terminal 22 and terminal 40.
connector P-C41 (WP 0009, Figure
There should be no continuity.
68) to implement 1 ECM J1 (WP
0009, Figure 69) (WP 0268).
Proceed to step 3.
wiring harness (WP 0266).
Connect front attachment wiring
harness connector U-C27 (WP 0009,
Figure 226) to articulate right solenoid
(WP 0009, Figure 227) (WP 0180).
Proceed to step 3.
3. Using MSD (WP 0006), select
2172-03 Code Active - Repeat
implement 120M ECM and verify
troubleshooting code from the
2172-03 is not active.
beginning.
2172-03 Code Not Active -
Troubleshooting complete.
2172-13 Articulate Right
System Response:
ECM will log diagnostic code.
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
0030-32