TM 5-3805-293-23-2
0030
Table 1. Implement Code (2169-03 to 2182-13) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2172-05 Articulate Right
System Response:
Solenoid Current Below Nor- ECM will log diagnostic code.
mal
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Test for Active Code.
1. Using MSD (WP 0006), select
2172-05 Code Active - Proceed to
implement 120M and verify 2172-
Test Step 2.
05 is active.
2172-05 Code Not Active -
Troubleshooting complete.
Test Step 2. Test for Faulty
Articulate Right Solenoid.
1. Turn ignition switch and battery
disconnect switch to the OFF
position.
2. Disconnect front attachment wir-
ing harness connector U-C27
(WP 0009, Figure 226) from artic-
ulate right solenoid (WP 0009,
Figure 227) (WP 0180).
3. Connect jumper wire between
front attachment wiring harness
connector U-C27 (WP 0009, Fig-
ure 226) terminal 1 and terminal
2.
2172-06 Code Active - Replace
4. Using MSD (WP 0006), select
implement 120M and check if
code 2172-06 becomes active.
Proceed to step 5.
2172-05 Code Remains Active -
Proceed to Test Step 3.
5. Using MSD (WP 0006), select
2172-05 Code Active - Repeat
implement 120M ECM and verify
troubleshooting code from the
2172-05 is not active.
beginning.
2172-05 Code Not Active -
Troubleshooting complete.
0030-28