TM 5-3805-293-23-2
0030
Table 1. Implement Code (2169-03 to 2182-13) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2172-06 Articulate Right
Test Step 2. Test for Faulty
Articulate Right Solenoid.
Normal - Continued
1. Turn ignition switch and battery
disconnect switch to the OFF
position.
2. Disconnect front attachment wir-
ing harness connector U-C27
(WP 0009, Figure 226) from artic-
ulate right solenoid (WP 0009,
Figure 227) (WP 0180).
3. Using MSD (WP 0006), select
2172-05 Code Active - Replace
implement 120M and check if
code 2172-05 becomes active.
Proceed to step 4.
2172-06 Code Remains Active -
Proceed to Test Step 3.
4. Using MSD (WP 0006), select
2172-06 Code Active - Repeat
implement 120M ECM and verify
troubleshooting code from the
2172-06 is not active.
beginning.
2172-06 Code Not Active -
Troubleshooting complete.
Test Step 3. Test for Shorted Cab
Lower Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to the OFF
position.
2. Disconnect cab lower wiring har-
ness connector P-C41 (WP 0009,
Figure 68) from implement 1 ECM
J1 (WP 0009, Figure 69) (WP
0268).
sure for continuity between cab
lower wiring harness connector P-
ECM (WP 0268).
C41 (WP 0009, Figure 68) termi-
Connect front attachment wiring
nal 52 and terminal 50. There
harness connector U-C27 (WP 0009,
should be no continuity.
Figure 226) to articulate right solenoid
(WP 0009, Figure 227) (WP 0180).
Proceed to step 4.
4. Using MSD (WP 0006), select
2172-03 Code Active - Repeat
implement 120M ECM and verify
troubleshooting code from the
2172-03 is not active.
beginning.
2172-03 Code Not Active -
Troubleshooting complete.
0030-31