TM 5-3805-293-23-2
0030
Table 1. Implement Code (2169-03 to 2182-13) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2172-05 Articulate Right
Test Step 3. Test for Open Cab
Solenoid Current Below Nor- Lower Wiring Harness.
mal - Continued
1. Disconnect cab lower wiring har-
ness connector P-C41 (WP 0009,
Figure 68) from implement 1 ECM
J1 (WP 0009, Figure 69) (WP
0268).
Resistance Less Than 5.0 Ohms -
Replace implement 1 ECM (WP
lower wiring harness connector P-
0268).
C41 (WP 0009, Figure 68) termi-
Remove jumper wire between front
nal 52 and terminal 50.
attachment wiring harness connector
U-C27 (WP 0009, Figure 226)
5.0 ohms.
terminal 1 and terminal 2.
Connect front attachment wiring
harness connector U-C27 (WP 0009,
Figure 226) to articulate right solenoid
(WP 0009, Figure 227) (WP 0180).
Proceed to step 3.
Proceed to Test Step 4.
3. Using MSD (WP 0006), select
2172-05 Code Active - Repeat
implement 120M ECM and verify
troubleshooting code from the
2172-05 is not active.
beginning.
2172-05 Code Not Active -
Troubleshooting complete.
Test Step 4. Test for Open Front
Attachment Wiring Harness.
1. Disconnect front attachment wir-
ing harness connector U-C1 (WP
0009, Figure 121) from cab lower
wiring harness connector P-C50
(WP 0009, Figure 120) (WP
0180).
0030-29