TM 5-3805-293-23-2
0030
Table 1. Implement Code (2169-03 to 2182-13) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2171-06 Articulate Left Sole-
4. Using MSD (WP 0006), select
2171-03 Code Active - Repeat
noid Current Above Normal -
implement 120M ECM and verify
troubleshooting code from the
Continued
2171-03 is not active.
beginning.
2171-03 Code Not Active -
Troubleshooting complete.
Test Step 4. Test for Shorted Front
Attachment Wiring Harness.
1. Disconnect front attachment wir-
ing harness connector U-C1 (WP
0009, Figure 121) from cab lower
wiring harness connector P-C50
(WP 0009, Figure 120) (WP
0180).
sure for continuity between front
attachment wiring harness (WP
attachment wiring harness con-
0180).
nector U-C1 (WP 0009, Figure
Connect cab lower wiring harness
121) terminal 21 and terminal 40.
connector P-C41 (WP 0009, Figure
There should be no continuity.
68) to implement 1 ECM J1 (WP
0009, Figure 69) (WP 0268).
Proceed to step 3.
wiring harness (WP 0266).
Connect front attachment wiring
harness connector U-C26 (WP 0009,
(WP 0009, Figure 225) (WP 0180).
Proceed to step 3.
3. Using MSD (WP 0006), select
2171-03 Code Active - Repeat
implement 120M ECM and verify
troubleshooting code from the
2171-03 is not active.
beginning.
2171-03 Code Not Active -
Troubleshooting complete.
0030-24