Table 1. Implement Code (2169-03 to 2182-13) Troubleshooting Procedures - Continued.
Table 1. Implement Code (2169-03 to 2182-13) Troubleshooting Procedures - Continued.

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  863    864    865    866    867  868  869    870    871    872    873  
img
. .
TM 5-3805-293-23-2
0030
Table 1. Implement Code (2169-03 to 2182-13) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2171-13 Articulate Left Sole-
System Response:
noid Out of Calibration
ECM will log diagnostic code.
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Test for Active Code.
1. Using MSD (WP 0006), select
2171-13 Code Active - Proceed to
implement 120M and verify 2171-
Test Step 2.
13 is active.
2171-13 Code Not Active -
Troubleshooting complete.
Test Step 2. Verify Other Diagnostic
Codes are Not Active.
1. Using MSD (WP 0006) verify
2171-03, 2171 05, or 2171-06 Code
2171-03, 2171-05, or 2171-06 are
Active - Troubleshoot other
not active.
diagnostic codes first in this work
package.
2171-13 Code Only Active - Proceed
to step 2.
2. Calibrate articulate left solenoid,
Articulate Left Solenoid Cannot Be
refer to Any Implement Moves
Calibrated - Replace articulate left
with Joystick in Hold Position (WP
solenoid (WP 0245).
0025).
Proceed to step 3.
Articulate Left Solenoid Calibrated
- Proceed to step 3.
3. Using MSD (WP 0006), select
2171-13 Code Active - Repeat
implement 120M ECM and verify
troubleshooting code from the
2171-13 is active.
beginning.
2171-13 Code Not Active -
Troubleshooting complete.