TM 5-3805-293-23-2
0030
Table 1. Implement Code (2169-03 to 2182-13) Troubleshooting Procedures.
0030
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2169-03 Circle Sideshift Left System Response:
Solenoid Voltage Above Nor- ECM will log diagnostic code.
mal
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Test for Active Code.
1. Using the MSD (WP 0006). Select
2169-03 Code Active - Proceed to
implement control #2 and verify
Test Step 2.
2169-03 is active.
2169-03 Code Not Active -
Troubleshooting complete.
Test Step 2. Test for Shorted Cab
Lower Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to the OFF
position.
2. Disconnect front attachment wir-
ing harness connector U-C43
(WP 0009, Figure 220) from circle
sideshift left solenoid (WP 0009,
Figure 221) (WP 0180).
3. Disconnect cab lower wiring har-
ness connector P-C45 (WP 0009,
Figure 72) from implement 2 ECM
J1 (WP 0009, Figure 73) (WP
0268).
sure for continuity between cab
lower wiring harness connector P-
ECM (WP 0268).
C45 (WP 0009, Figure 72) termi-
Connect front attachment wiring
nal 48 and all other P-C45 termi-
harness connector U-C43 (WP 0009,
nals. There should be no
Figure 220) to circle sideshift left
continuity.
0180).
Proceed to step 5.