TM 5-3805-293-23-2
0029
Table 1. Implement Code (2160-03 TO 2168-13) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2168-06 Circle Right Sole-
6. Using MSD (WP 0006), select
2168-06 Code Active - Repeat
noid Current Above Normal -
Implement 120M and verify 2168- troubleshooting code from the
Continued
06 is active.
beginning.
2168-06 Code Not Active -
Troubleshooting complete.
2168-13 Circle Right Sole-
System Response:
ECM will log a diagnostic code.
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is Active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Verify if Code 2168-13
is Active.
1. Connect MSD (WP 0006). Select 2168-13 Code Active - Proceed to
Implement 120M and verify 2168- Test Step 2.
13 is active.
2168-13 Code Not Active -
Troubleshooting complete.
Test Step 2. Verify Other Diagnostic
Codes are Not Active.
1. Using MSD (WP 0006) verify
2168-03, 2168-05, or 2168-06 Code
2168-03, 2168-05, or 2168-06 are
Active - Troubleshoot other
not active.
diagnostic codes first in this work
package.
2168-13 Code Only Active - Proceed
to step 2.
2. Calibrate circle right solenoid,
refer to Any Implement Moves
Calibrated - Replace circle left
with Joystick in Hold Position (WP
Proceed to step 3.
Circle Right Solenoid Calibrated -
Proceed to step 3.
3. Using MSD (WP 0006), select
2168-13 Code Active - Repeat
Implement 120M and verify 2168- troubleshooting code from the
13 is active.
beginning.
2168-13 Code Not Active -
Troubleshooting complete.
END OF WORK PACKAGE