TM 5-3805-293-23-2
0029
Table 1. Implement Code (2160-03 TO 2168-13) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2165-03 Blade Sideshift Left System Response:
Solenoid Voltage Above Nor- ECM will log a diagnostic code.
mal
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is Active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Verify if Code 2165-03
is Active.
1. Connect MSD (WP 0006). Select 2165-03 Code Active - Proceed to
Implement 120M and verify 2165- Test Step 2.
03 is active.
2165-03 Code Not Active -
Troubleshooting complete.
Test Step 2. Test Implement 1 ECM.
1. Turn ignition switch and battery
disconnect switch to the OFF
position (TM 5-3805-293-10).
2. Remove front frame nose cover
(WP 0224).
3. Disconnect front attachment har-
ness connector U-C45 (WP 0009,
Figure 250) from blade sideshift
251).
4. Disconnect cab lower harness
connector P-C41 (WP 0009, Fig-
ure 68) from implement 1 ECM J1
(WP 0009, Figure 69) (WP 0268).
0029-34