TM 5-3805-293-23-2
0029
Table 1. Implement Code (2160-03 TO 2168-13) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2163-06 Blade Right Lower
6. Using MSD (WP 0006), select
2163-06 Code Active - Repeat
Implement 120M and verify 2163- troubleshooting code from the
Normal - Continued
06 is active.
beginning.
2163-06 Code Not Active -
Troubleshooting complete.
2163-13 Blade Right Lower
System Response:
ECM will log a diagnostic code.
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is Active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Verify if Code 2163-13
is Active.
1. Connect MSD (WP 0006). Select 2162-13 Code Active - Proceed to
Implement 120M and verify 2163- Test Step 2.
13 is active.
2162-13 Code Not Active -
Troubleshooting complete.
Test Step 2. Verify Other Diagnostic
Codes are Not Active.
1. Using MSD (WP 0006) verify
2163-03, 2163 05, or 2163-06 Code
2163-03, 2163-05, or 2163-06 are
Active - Troubleshoot other
not active.
diagnostic codes first in this work
package.
2163-13 Code Only Active - Proceed
to step 2.
Blade Right Lower Solenoid
2. Calibrate blade right lower sole-
Cannot Be Calibrated - Replace
noid, refer to Any Implement
blade right lower solenoid (WP 0246).
Moves with Joystick in Hold Posi-
Proceed to step 3.
Blade Right Lower Solenoid
Calibrated - Proceed to step 3.
3. Using MSD (WP 0006), select
2163-13 Code Active - Repeat
Implement 120M and verify 2163- troubleshooting code from the
13 is active.
beginning.
2163-13 Code Not Active -
Troubleshooting complete.
0029-33