• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. Implement Code (2160-03 TO 2168-13) Troubleshooting Procedures - Continued.
Table 1. Implement Code (2160-03 TO 2168-13) Troubleshooting Procedures - Continued.

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  803    804    805    806    807  808  809    810    811    812    813  
img
TM 5-3805-293-23-2
0029
Table 1. Implement Code (2160-03 TO 2168-13) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2163-05 Blade Right Lower
7. Using digital multimeter, test for
Resistance 5.0 Ohms or Less -
Solenoid Current Below Nor-
continuity between harness con-
Replace implement 1 ECM (WP
mal - Continued
nector P-C41 (WP 0009, Figure
0268).
68) terminal 62 and terminal 60.
Remove jumper wire from harness
Resistance should be less than
connector P-C50 (WP 0009, Figure
5.0 ohms.
120) terminal 17 and terminal 39.
Connect front attachment harness
connector U-C22 (WP 0009, Figure
236) to blade right lower solenoid (WP
0009, Figure 237), and install rear
front frame cover (WP 0224).
Proceed to step 8.
Resistance More Than 5.0 Ohms -
Replace cab lower wiring harness
(WP 0266).
Connect front attachment harness
connector U-C22 (WP 0009, Figure
236) to blade right lower solenoid (WP
0009, Figure 237), and install rear
front frame cover (WP 0224).
Proceed to step 8.
8. Using MSD (WP 0006), select
2163-05 Code Active - Repeat
Implement 120M and verify 2163- troubleshooting code from the
05 is active.
beginning.
2163-05 Code Not Active -
Troubleshooting complete.