Table 1. Implement Code (2146-02 to 2156-08) Troubleshooting Procedures - Continued.
Table 1. Implement Code (2146-02 to 2156-08) Troubleshooting Procedures - Continued.

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  697    698    699    700    701  702  703    704    705    706    707  
img
TM 5-3805-293-23-2
0028
Table 1. Implement Code (2146-02 to 2156-08) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2146-03 Articulation Lever
6. Using digital multimeter, measure
Resistance Less Than 5.0 Ohms -
Position Sensor Voltage
for continuity between cab lower
Proceed to Test Step 8.
Above Normal - Continued
wiring harness connector P-C39
Resistance 5.0 Ohms or Greater -
(WP 0009, Figure 70) terminal 26
Replace cab lower wiring harness
and P-C41 (WP 0009, Figure 68)
(WP 0266).
terminal 21.
Proceed to step 7.
Resistance should be less than
5.0 ohms.
7. Using MSD (WP 0006), select
2146-03 Code Active - Repeat
Implement 120M ECM and verify
troubleshooting code from the
2146-03 is not active.
beginning.
2146-03 Code Not Active -
Troubleshooting complete.
Test Step 8. Test for Shorted Cab
Lower Wiring Harness.
1. Remove jumper wire between cab
lower wiring harness connector P-
C52 (WP 0009, Figure 154) termi-
nal 1 and P-C48 (WP 0009, Fig-
ure 116) terminal 3.
2. Using digital multimeter, measure
Continuity - Replace cab lower wiring
for continuity between cab lower
harness (WP 0266).
wiring harness connector P-C39
Proceed to step 3.
(WP 0009, Figure 70) terminal 26
No Continuity - Replace implement 1
and all other P-C39 terminals and
ECM (WP 0268).
all P-C41 terminals. There should
Connect cab lower wiring harness
be no continuity.
connector P-C52 (WP 0009, Figure
154) to LH joystick connector J2 (WP
0282).
Connect the cab lower wiring harness
connector P-C48 (WP 0009, Figure
116) to LH joystick connector J3 (WP
0282).
Proceed to step 3.
3. Using MSD (WP 0006), select
2146-03 Code Active - Repeat
Implement 120M ECM and verify
troubleshooting code from the
2146-03 is not active.
beginning.
2146-03 Code Not Active -
Troubleshooting complete.
0028-9