Table 1. Implement Code (2146-02 to 2156-08) Troubleshooting Procedures - Continued.
Table 1. Implement Code (2146-02 to 2156-08) Troubleshooting Procedures - Continued.

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  702    703    704    705    706  707  708    709    710    711    712  
img
TM 5-3805-293-23-2
0028
Table 1. Implement Code (2146-02 to 2156-08) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2146-08 Articulation Lever
6. Using digital multimeter, measure
Resistance Less Than 5.0 Ohms -
Position Sensor Abnormal
for continuity between cab lower
Replace implement 1 ECM (WP
Frequency, Pulse Width or
wiring harness connector P-C39
0268).
Period - Continued
(WP 0009, Figure 70) terminal 26
Remove jumper wire from cab lower
and P-C41 (WP 0009, Figure 68)
wiring harness connector P-C52 (WP
terminal 21.
0009, Figure 154) terminal 1 and P-
Resistance should be less than
C48 (WP 0009, Figure 116) terminal
5.0 ohms.
3.
Connect cab lower wiring harness
connector P-C52 (WP 0009, Figure
154) to LH joystick connector J2 (WP
0282).
Connect the cab lower wiring harness
connector P-C48 (WP 0009, Figure
116) to LH joystick connector J3 (WP
0282).
Proceed to step 7.
Resistance 5.0 Ohms or Greater -
Replace cab lower wiring harness
(WP 0266).
Proceed to step 7.
7. Using MSD (WP 0006), select
2146-08 Code Active - Repeat
Implement 120M ECM and verify
troubleshooting code from the
2146-08 is not active.
beginning.
2146-08 Code Not Active -
Troubleshooting complete.